Timing Parameters
CuBIE has three groups of timing parameters: integration bounds define the overall time span, output timing parameters control when results are saved, and step size parameters control how the integrator advances through time.
We use this system in the examples on this page:
import numpy as np
from cubie import Solver, create_ODE_system, solve_ivp
LV = create_ODE_system(
"""
dx = a*x - b*x*y
dy = -c*y + d*x*y
""",
parameters={"a": 0.1, "b": 0.02, "c": 0.3, "d": 0.01},
states={"x": 0.5, "y": 0.3},
)
b_values = np.linspace(0.01, 0.05, 10000)
Integration Bounds
Three parameters define the time span of integration:
duration
Total length of the recorded integration in simulation time units. This is the time span over which outputs are saved.
Default:
1.0Type:
float
# Integrate for 100 time units
result = solve_ivp(
LV, parameters={"b": b_values}, method="ode45", duration=100.0
)
t0
Starting time of the integration. Affects time-dependent drivers and the timestamps in output arrays.
Default:
0.0Type:
float
# Start integration at t=5.0
result = solve_ivp(
LV,
parameters={"b": b_values},
method="ode45",
t0=5.0,
duration=10.0,
)
# Cubie records output from t=5.0 to t=15.0
settling_time
Lead-in period before recording begins. The integrator runs for this
duration starting from t0, but no output is saved. This is useful
for allowing transients to decay before collecting data.
Default:
0.0Type:
float(non-negative)
# Let the system settle for 50 time units, then record 100
result = solve_ivp(
LV,
parameters={"b": b_values},
method="ode45",
settling_time=50.0,
duration=100.0,
)
# Cubie integrates from t=0 to t=150 and records from t=50 to t=150
The total integration time is settling_time + duration. The
integration starts at t0 and runs until t0 + settling_time + duration.
Example: t0=5, settling_time=20, duration=50
t=5 t=25 t=75
| | |
|<-- settling_time ->|<------------ duration --------------->|
| (20) | (50) |
| | |
+--------------------+---------------------------------------+
^ ^ ^
| | |
Integration Recording Integration
starts starts ends
(no output) (output saved)
Output Timing Parameters
Output timing controls how often CuBIE records results during integration.
save_every
Time interval between saved state and observable snapshots. Each saved
point includes the current time, state values, and observable values
(depending on your output_types setting).
Default: If not specified but state/observable outputs are requested, CuBIE saves only at the start (t=0 or t=settling_time) and end of the integration (“save_last” mode).
Type:
float(seconds of simulation time)
# Save state every 0.1 seconds of simulation time
result = solve_ivp(
LV,
parameters={"b": b_values},
method="ode45",
save_every=0.1,
duration=10.0,
)
# Cubie saves 101 points, including t=0
# Without save_every, cubie saves only the first and last points
result = solve_ivp(
LV,
parameters={"b": b_values},
method="ode45",
duration=10.0,
output_types=["state"],
)
summarise_every
Length of each summary window. CuBIE uses fixed, non-overlapping windows for summary statistics. At the end of each window, metrics (mean, max, RMS, etc.) are computed from all samples taken during that window, written to output, and the accumulator resets for the next window.
Default: If not specified but summary outputs are requested, one summary is calculated and saved at the end of the integration.
Type:
float(seconds of simulation time)
# Summarise over 10 windows, each 1 second long
result = solve_ivp(
LV,
parameters={"b": b_values},
method="ode45",
summarise_every=1.0,
sample_summaries_every=0.1,
duration=10.0,
output_types=["mean"],
)
# Without summarise_every, cubie saves one summary at the end
result = solve_ivp(
LV,
parameters={"b": b_values},
method="ode45",
sample_summaries_every=0.1,
duration=10.0,
output_types=["mean"],
)
sample_summaries_every
Sampling interval within each summary window. This controls how many samples contribute to each summary calculation. At each sample point, the current state/observable values are fed into the running accumulator (e.g., added to a running sum for mean calculation, compared against current max, etc.).
Required whenever summary outputs are requested; a solve without it raises
ValueError.Type:
float(seconds of simulation time)Constraint:
summarise_every, when set, must be an integer multiple ofsample_summaries_every;sample_summaries_everymust fit insideduration.
# Take 100 samples in each 1-second window
result = solve_ivp(
LV,
parameters={"b": b_values},
method="ode45",
sample_summaries_every=0.01,
summarise_every=1.0,
duration=10.0,
output_types=["mean", "max"],
)
Higher sampling rates give more accurate summaries but increase computational overhead.
Summary Window Behaviour
The summary system uses fixed, non-overlapping windows:
At each
sample_summaries_everyinterval, current values are sampled and fed into accumulators (running sum, running max, etc.)At each
summarise_everyinterval, final metrics are computed from the accumulators, written to output, and accumulators resetThe next window starts fresh with no memory of previous windows
This differs from sliding-window approaches where windows overlap.
Timeline with summarise_every=1.0, sample_summaries_every=0.25:
t=0.0 t=0.25 t=0.5 t=0.75 t=1.0 t=1.25 ...
| | | | | |
S S S S S+W S ...
S = sample taken, W = window closes (summary written, reset)
You can set save_every independently of the summary intervals, so
you can save states often while you summarise over long windows, or the
reverse.
Step Size Parameters
Adaptive controllers use three related parameters to control step sizes:
dt: Initial step size (starting point for adaptation)dt_min: Minimum allowable step size (floor)dt_max: Maximum allowable step size (ceiling)
Fixed-step controllers use only dt, which becomes the constant step
size throughout integration.
If you use a fixed-step controller, set dt 10 to 100 times smaller
than the sharpest corner in your system’s solution. If you use an
adaptive controller, set dt_max shorter than any quasi-periodic
cycle in the solution, so that cubie can’t step straight over a cycle
and land back near where it started. If cubie reports
STEP_TOO_SMALL in a run’s status code and dt_min is not much
smaller than the sharpest feature in the solution, decrease dt_min.
If dt_min is already very small, try an algorithm designed for
stiff systems (see
Choosing an Algorithm). When you
give an adaptive controller no dt, cubie estimates a starting step
for each run. You only need to set dt if you run many short
integrations and you know a starting step that suits them better than
cubie’s estimate.
Default Behaviour
When you don’t specify any step size parameters, CuBIE uses these defaults:
Controller |
Parameter |
Default Value |
|---|---|---|
Adaptive |
|
|
Adaptive |
|
|
Adaptive |
|
Estimated for each run |
Fixed |
|
|
When you give an adaptive controller no dt, CuBIE estimates each
run’s starting step with Hairer’s method, which is the best choice in
most cases.
Derivation Rules
When you provide some parameters but not others, CuBIE derives the missing values. The rules differ for adaptive and fixed controllers:
Adaptive controllers:
You Provide |
CuBIE Derives |
|---|---|
|
|
|
|
|
|
|
Nothing derived |
|
|
|
|
All three |
Nothing derived (all values used as given) |
Fixed-step controllers:
A fixed controller uses dt as its step, or 1e-3 if you don’t give
one.
Build a Solver to read the step sizes cubie derives:
# Give an adaptive controller dt, and cubie derives the bounds
solver = Solver(LV, algorithm="ode45", dt=0.01)
print(solver.dt_min, solver.dt, solver.dt_max)
# cubie derives dt_min=1e-8 and dt_max=10.0
# Give the bounds, and cubie estimates each run's starting step
solver = Solver(LV, algorithm="ode45", dt_min=1e-5, dt_max=0.1)
print(solver.dt_min, solver.dt_max)
# Set a fixed step of dt=0.005
solver = Solver(LV, algorithm="ode45", step_controller="fixed", dt=0.005)
print(solver.dt)
Update Behaviour
When you call solver.update() to change step parameters mid-session,
CuBIE tracks which values you originally set versus which were derived:
User-set values are preserved and never automatically adjusted
Derived values may be adjusted if they become inconsistent with your changes
For example, if you give only dt=0.01, cubie derives dt_min=1e-8
and dt_max=10.0. If you then update dt=0.001, cubie derives the
bounds again from your new dt, as 1e-9 and 1.0. If you had also
given dt_min=1e-4 yourself, cubie keeps it at 1e-4 and derives only
dt_max.
Complete Example
This example shows all timing parameters working together:
solver = Solver(LV, algorithm="ode45")
result = solver.solve(
initial_values={"x": np.linspace(0.1, 2.0, 100)},
parameters={"b": np.linspace(0.01, 0.05, 100)},
# Integration bounds
t0=0.0,
settling_time=10.0, # Discard first 10 time units
duration=100.0, # Record 100 time units after settling
# Output timing
save_every=0.1, # Save states every 0.1 time units
summarise_every=10.0, # Compute summaries every 10 time units
sample_summaries_every=0.05, # Sample for summaries every 0.05 units
# Step size (adaptive controller)
dt=0.01, # Start at 0.01; cubie derives bounds of 1e-8 to 10.0
# What to save
output_types=["state", "mean", "max"],
)
# Timeline:
# t=0 to t=10: settling (no output saved)
# t=10 to t=110: recording period
# - 1001 state saves (every 0.1 from t=10 to t=110)
# - 10 summary windows (every 10.0 from t=10 to t=110)
# - 200 samples per summary window (every 0.05 over 10.0)